SERIES 500 – ABSOLUTE Digimatic Solar Caliper
Technical Data • Mitutoyo's Absolute Solar Digimatic Caliper • Slider operation is smooth and comfortable.
retains its origin point indefinitely. • An ABSOLUTE scale is incorporated so that zero
Scale type: ABSOLUTE electrostatic linear encoder • At 60 Lux and above the ABSOLUTE solar caliper setting is not required at each power ON. No
is ready to start measurement. No more repeated danger of overspeed errors.
Max. response speed: Unlimited zero setting caused by a shortage of light. • Allows integration into statistical process control
• Can measure outside and inside dimensions, and measurement systems for models with
Power supply: Solar cell*1 depth, and steps. measurement data output connector.
Operational
temperature: 0 to 40°C
*1 Can be used continuously above 60 lux ambient illumination
Functions D
ABSOLUTE system measurement: 500-464
After power is turned ON, measurement can be started
without zero-setting if origin-setting was previously SPECIFICATIONS
performed. The ABS (absolute) origin position can be changed
by the ORIGIN button. Inch/Metric
Zero-setting (INC measurement mode): Code No. Range Resolution Accuracy* Repeatability Price
Displayed value can be set to zero at any arbitrary position of 0.01 mm 201.00
the slider for comparative measurements. With SPC data output 0.01 mm 238.00
143.00
Data output: 500-464 0-150 mm (0-6") 173.00
Models equipped with this function have an output port for
transferring measurement data to a Statistical Process Control Unit: mm
(SPC) system.
Data hold:
By using the data hold unit (option), the displayed value can
be held. This cannot be used with the data output function.
Inch/mm selection:
Switches the units of measurement (at any time).
Alerts:
In the unlikely event of a display overflow or calculation
error, an error message is displayed and measurement stops.
Measurement cannot continue until the error is corrected. If
contamination on the surface of the scale causes a calculation
error, an error message is displayed and measurement stops.
Optional Accessories 500-465 0-200 mm (0-8") 0.01 mm (.0005") ±0.02 mm (±.001")
(Only for models with data output function) Without SPC data output
959149: SPC data cable with pushbutton (1 m) 500-474 0-150 mm (0-6") 0.01 mm (.0005") ±0.02 mm (±.001")
34.60 500-475 0-200 mm (0-8")
959150: SPC data cable with pushbutton (2 m) * Excluding quantizing error.
39.40
06ADV380C: USB Input Tool Direct USB-ITN-A (2 m) DIMENSIONS
90.80
02AZD790C: SPC data cable for U-WAVE-T (160 mm)
52.20 D
02AZE140C: SPC data cable for U-WAVE-T and footswitch
(160/500 mm) AB
114.00 C
E
959143: Data hold unit Range ABCD E
17.00 0-150 mm 40 21 16.5 233 6
0-200 mm 50 24.5 20 290
Smooth slider movement makes for
comfortable operation.
High quality guide surface finish for smooth slider
movement.
Conventional ABSOLUTE Solar Caliper
Ra: 0.126 m Ra: 0.071 m
Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances. D-10 500-454 CD-S15CT
Therefore the company reserves the right to change any or all aspects of any product specification without notice.
mitutoyo@mitutoyo-tools.ru www.mitutoyo-tools.ru