Ниже представлена эта же страница в формате, позволяющем производить копирование текста.

Mitutoyo - Полный каталог инструмента - 2014 Английский язык

                                                           для размещения заказа - mitutoyo@mitutoyo-tools.ru

Micrometers

SERIES 293 – ABSOLUTE Digimatic High-Accuracy Micrometer

•	A world-leading 0.1 m resolution makes this •	Transfer of body heat to the instrument is                                  Technical Data

	 micrometer ideal for customers who need to                             	 reduced by a (removable) heat shield, minimizing  Measuring force:		  7 to 9N
                                                                                                                             Power supply:		     Lithium battery (CR2032) x 1
	 make highly accurate measurements with a hand- 	 error caused by thermal expansion of the frame                            Battery life:		     Approx. two years when used under 	
                                                                                                                             			                 normal conditions
	 held tool.                                                             	 when performing handheld measurements.

•	The High-Accuracy Digimatic Micrometer utilizes •	The ABS sensor also eliminates the need to                               Functions

	 Mitutoyo’s innovative 0.1 m resolution ABS                            	 perform origin setting each time the power is     Preset (ABS measurement system):
                                                                                                                             The measurement origin can be preset to any value within the
	 (absolute) rotary sensor*1 and high-accuracy                           	 turned on, letting you start measuring straight   display range for convenience in measuring.
                                                                                                                             Zero-setting (INC measurement system):
	 screw machining technology to reduce the                               	 away. With no possibility of overspeed errors,    The display can be zeroed at any position of the spindle,
B 	 instrumental error to ±0.5 m, delivering higher 	 this micrometer also delivers a higher level of                       making comparison measurement easier. Returning to the
                                                                                                                             absolute-measurement mode is easily accomplished.
	 accuracy without sacrificing operability.                              	 reliability.                                      Hold:
                                                                         •	A range of features enables flexible              Pressing the HOLD button freezes the current value in the
*1	 Patent pending in Japan, the United States of America, the European  	 measurement, including switchable resolution      display. This function is useful for preserving a measurement
	 Union, and China.                                                      	 (0.0001/0.0005 mm), function lock and             in situations of poor visibility when the instrument must be
                                                                         	 preset.                                           moved away from the workpiece before the reading can be
•	A highly rigid frame and high-performance                                                                                  recorded.
	 constant-force mechanism*2 enable more stable                                                                              Resolution switching:
	 measurement, while the clicks emitted while the                                                                            The resolution of the display can be switched. If 0.1 m
                                                                                                                             measurement is not required, the resolution can be switched
	 workpiece is being measured assure the operator                                                                            to 0.5 m.
                                                                                                                             Function lock:
	 that measurement is proceeding normally.                                                                                   Functions such as preset or zero-set can be locked to avoid
                                                                                                                             inadvertently changing the origin position.
*2	 Patent pending in Japan, the United States of America, the European                                                      On/off:
	 Union, and China.                                                                                                          The power can be turned off after measurement is complete.
                                                                                                                             Even after the power is turned off, the origin or last zero-set
                                                                                  Function lock                              position remains in the memory.
                                                                                                                             Auto power off:
                                                                                                                             Even if the power is left on, the power turns off automatically
                                                                                                                             if the micrometer is not used within a 20-minute period.
                                                                                                                             Measurement data output:
                                                                                                                             Measurement data can be output, allowing easy incorporation
                                                                                                                             of this instrument into a statistical process control or
                                                                                                                             measurement system.
                                                                                                                             Error alarm:
                                                                                                                             In the unlikely event of a display overflow or calculation
                                                                                                                             error, an error message is displayed and measurement stops.
                                                                                                                             Measurement cannot continue until the error is corrected.
                                                                                                                             Also, if the battery voltage drops below a certain point, the
                                                                                                                             battery indicator will turn on before measurement becomes
                                                                                                                             impossible, warning the user that the battery needs to be
                                                                                                                             replaced.

                                                                         293-130

SPECIFICATIONS

Code No.                      Range       Resolution            Accuracy* Measuring surface      Mass        Price
                                     0.0001/0.0005 mm    ±0.5 µm (±.00002") 3.2 mm            400 g  1320.00
293-130      0-25 mm              (.000005"/.00002")
               (0-1")
                                          switchable

* Excluding quantizing error

                                                           B-3                                      Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.
                                                                                                                                  Therefore the company reserves the right to change any or all aspects of any product specification without notice.

                                                                         mitutoyo@mitutoyo-tools.ru www.mitutoyo-tools.ru
Заявка