Ниже представлена эта же страница в формате, позволяющем производить копирование текста.

Mitutoyo - Полный каталог инструмента - 2014 Английский язык

                                                                                  для размещения заказа - mitutoyo@mitutoyo-tools.ru

Micrometers

SERIES 293 – QuantuMike Fast Action Waterproof Digimatic Micrometer

•	Advanced pioneering technology has created                                         •	A graduated scale is provided on the sleeve for      Technical Data

	 the next generation of micrometer, the most                                        	 use with a reference mark on the thimble so that     Dust/Water
                                                                                                                                            protection level: 	
	 revolutionary advance in micrometer technology 	 every millimetre displacement can be checked to                                                               IP65 (IEC60529)*2

	 since James Watt invented the instrument.                                          	 provide extra confidence.                            Measuring force: 	 7 to 12N

•	Faster measurement is achieved by using a                                                                                                 Length standard: 	 Electromagnetic rotary sensor
	 coarser thread which feeds the spindle by 2 mm
	 per revolution of the thimble. This increase in                                                                                           Battery life: 		     Approx. 1.2 years under normal use

                                                                                                                  Reference mark            Standard accessories: 	 Setting standard 1 pc (except for 	

	 thread lead has been made possible thanks to                                                                                              			                  0-25 mm/0-1" models)

                                                                                                                                            			                  Button type silver oxide battery

B 	 new high precision thread-cutting and testing                                                                                           			                  (SR44, 938882), 1 pc
      	 techniques.
                                                                                     •	Those models that provide data output allow easy     			                  Spanner (301336), 1 pc
                                                                                     	 incorporation of this instrument into a statistical
                                                                                                                                            *2 Anti-corrosion treatment is required after use.

                                                     Spindle feed per revolution     	 process control or measurement system.               Functions
                                                                                     •	There is a choice of convenient Interface Input
1 revolution of thimble                Conventional                                  	 Tools which enable the conversion of                 Origin point setting (ABS measurement system):
                                       model                                         	 measurement data to keyboard signals and             Pressing the ORIGIN button resets the ABS origin at the
                                                     0.5 mm                          	 directly input them to cells in off-the-shelf        current spindle position. Origin values can be set depending
                                                                                                                                            on each size.
                         QuantuMike                  2.0 mm

•	QuantuMike is equipped with a function lock                                        	 spreadsheet software such as Excel.                  Zero setting (INC measurement system):
	 feature to prevent the origin point being moved                                    •	Excellent resistance against oil, water and dust     A brief press on the ZERO/ABS button sets display to zero at
	 by mistake during measurement.                                                     	 (IP65 protection level) enables this product to be   the current spindle position and switches to the incremental
                                                                                     	 used in machining situations that include            (INC) measuring mode. A longer press resets to the ABS
     Function lock                                                                   	 splashing coolant fluid.                             measuring mode.
                                                                                     •	Measuring faces: Carbide.
                                                                                                                                            Hold:
                                                                                                                                            Pressing the HOLD button freezes the current value in the

                                                                                                                                            display. This function is useful for preserving a measurement

                                                                                                                                            in situations of poor visibility when the instrument must be

                                                                                                                                            moved away from the workpiece before the reading can be

                                                                                                                                            recorded.

                                                                                                                                            Function lock:

                                                                                                                                            This function allows the ORIGIN (origin point setting) function

                                                                                                                                            and the ZERO (zero setting) function to be locked to prevent

                                                                                                                                            these points being reset accidentally.

                                                                                                                                            Auto power ON/OFF:

                                                                                                                                            The reading on the LCD disappears after this instrument is

                                                                                                                                            idle for approx. 20 minutes, but the origin point is retained.

                                                     • Dust-tight and water                                                                 Turning the spindle causes the reading on the LCD to
                                                       jet protected IP65                                                                   reappear.

                                                                                                                                            Data output:

                                                                                  6                                                         Models equipped with this function have an output port for
                                                                 000002160                                                                  transferring measureent data to a Statistical Process Control

                                                                                                                                            (SPC) system.

                                                                                                                                            Error alarm:

                                                                                                                                            In the unlikely event of a display overflow or calculation

                                                                                     293-180                                                error, an error message is displayed and measurement stops.
                                                                                                                                            Measurement cannot continue until the error is corrected.

                                                                                                                                            Also, if the battery voltage drops below a certain point, the

                                                                                                                                            battery indicator will turn on before measurement becomes

                                                                                                                                            impossible, warning the user that the battery needs to be

                                                                                                                                            replaced.

SPECIFICATIONS

Inch/Metric

Code No.                        Range                Resolution     Accuracy*1        Flatness                    Parallelism        Price
                                                     0.001 mm                          0.3 µm
With SPC data output                                 (.00005")   ±1 µm (±.00005")    (.000012")                     1 µm          248.00
                                                     0.001 mm    ±2 µm (±.0001")       0.3 µm                     (.00004")       265.00
293-180                  0-25 mm (0-1")          (.00005")                       (.000012")                                   298.00
                                                                 ±1 µm (±.00005")                                   2 µm          331.00
293-181                  25-50 mm (1-2")                     ±2 µm (±.0001")                                  (.00008")
                                                                                                                                  167.00
293-182                  50-75 mm (2-3")                                                                        1 µm          231.00
                                                                                                                  (.00004")       243.00
293-183                  75-100 mm (3-4")                                                                                     267.00
                                                                                                                    2 µm
Without SPC data output                                                                                           (.00008")

293-185                  0-25 mm (0-1")

293-186                  25-50 mm (1-2")

293-187                  50-75 mm (2-3")

293-188                  75-100 mm (3-4")

*1 Excluding quantizing error.

                                                                 B-5                                            Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.
                                                                                                                                              Therefore the company reserves the right to change any or all aspects of any product specification without notice.

                                                                                     mitutoyo@mitutoyo-tools.ru www.mitutoyo-tools.ru
Заявка