Ниже представлена эта же страница в формате, позволяющем производить копирование текста.

Mitutoyo - Полный каталог инструмента - 2014 Английский язык

                                                     для размещения заказа - mitutoyo@mitutoyo-tools.ru

Micrometers

SERIES 293 – IP65 Digimatic Micrometer

•	Based on new waterproof structural technology, •	Further-Increased operability thanks to easy-to-                                Technical Data

	 this micrometer provides IP65 protection levels, 	 read LCD with 30% more character area.                                        Flatness: 		      0.3 m/.000012"

	 enabling use in environments that include                                  •	Models equipped with a Digimatic output port        Dust/water

	 cutting oil, etc.*                                                         	 can form part of a statistical process control or   protection level:	 IP65 (IEC60529) *2

	 * Anti-corrosion treatment is required after use.                          	 networked measurement system.                       Measuring force: 	 5 to 10N

•	±1 m instrumental error (75 mm/3" or less                               •	Interface Input Tools are available that enable     Battery life: 		  Approx. 1.2 years under normal use

	 measuring range models).                                                   	 the conversion of measurement data to keyboard      Standard accessories: 	 Setting standard, 1 pc (except for

•	Measuring data output function is available with 	 signals that are then directly input to cells in off-                         			               0-25 mm (0-1") models)

                                                                                                                                   			               Button type silver oxide battery

B 	 a water-resistant data cable to maintain the IP65 	 the-shelf spreadsheet software such as Excel.                              			               (SR44, 938882), 1 pc

	 protection level.                                                          •	Two types of constant-force devices are available:  			               Spanner (301336), 1 pc

•	Oil-resistant materials are used in all plastic                            	 Ratchet Stop and Ratchet Thimble.                   *2 Anti-corrosion treatment is required after use.

	 components.                                                                •	Measuring faces: Carbide                            Functions

•	Auto power ON/OFF function.                                                                                                      Origin point setting (ABS measurement system):
                                                                                                                                   Resets the ABS origin at the current spindle position to the
                                                     • Dust-tight and water6                                                       minimum value of the measuring range and switches to ABS
                                                       jet protected IP65                                                          mode.
                                                                000002160
                                                                                                                                   Zero setting (INC measurement system):
                                                                                      293-230                                      A brief press on the ZERO/ABS button sets display to zero at
                                                                                                                                   the current spindle position and switches to the incremental
                                                                                      293-334                                      (INC) measuring mode. A longer press resets to the ABS
                                                                                                                                   measuring mode.

                                                                                                                                   Hold:
                                                                                                                                   Pressing the HOLD button freezes the current value in the
                                                                                                                                   display. This function is useful for preserving a measurement
                                                                                                                                   in situations of poor visibility where the instrument must be
                                                                                                                                   moved away from the workpiece before the reading can be
                                                                                                                                   recorded.

                                                                                                                                   Data output:
                                                                                                                                   Models equipped with this function have an output port for
                                                                                                                                   transferring measurement data to a Statistical Process Control
                                                                                                                                   (SPC) system.

                                                                                                                                   Auto power ON/OFF:
                                                                                                                                   The reading on the LCD disappears after this instrument is
                                                                                                                                   idle for about 20 minutes, but the reading and measurement
                                                                                                                                   mode are retained. Turning the spindle causes the reading to
                                                                                                                                   reappear.

                                                                                                                                   Error alarm:
                                                                                                                                   In the unlikely event of a display overflow or calculation
                                                                                                                                   error, an error message is displayed and measurement stops.
                                                                                                                                   Measurement cannot continue until the error is corrected.
                                                                                                                                   Also, if the battery voltage drops below a certain point, the
                                                                                                                                   battery indicator will turn on before measurement becomes
                                                                                                                                   impossible, warning the user that the battery needs to be
                                                                                                                                   replaced.

                                                                                                                                   Function lock*3
                                                                                                                                   This function allows the ORIGIN (origin point setting) function
                                                                                                                                   and the ZERO (zero-setting ) function to be locked to prevent
                                                                                                                                   these points being reset accidentally.

                                                                                                                                   *3 All-digit preset type only.

                               293-230

293-231

                                                                             293-233                                                                                                   293-354-10

293-232

                                                     B-7                                                Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.
                                                                                                                                      Therefore the company reserves the right to change any or all aspects of any product specification without notice.

                                                                             mitutoyo@mitutoyo-tools.ru www.mitutoyo-tools.ru
Заявка