для размещения заказа - mitutoyo@mitutoyo-tools.ru
Optional Accessories
Objectives for Measuring Microscopes
Near-Infrared Corrected
M Plan Apo NIR for Bright Field Observation
Code No. Magnification Numerical Working Focal Resolving Focal View View field 2*2 Mass Price Note:
aperture distance distance power depth field 1*1 (mm) (g) These objectives are designed so that a workpiece's image can
(µm) 570.00 be focussed within the focal depth even when the wavelength
(mm) (mm) (µm) (mm) 220 952.00 used is changed anywhere from the visible range
14 250 1900.00 (l = 480 nm) up to near-infrared range (l = 1800 nm).
378-822-5 5X 0.14 37.5 40 2.0 4.1 4.8 0.96 x 1.28 300 1900.00 Therefore the M Plan NIR Series are suitable for laser repair.
1.7 315 2380.00 However, when the wavelength used exceeds 1100 nm, the
378-823-5 10X 0.26 30.5 20 1.1 1.6 2.4 0.48 x 0.64 335 5440.00 focussing position may slightly deviate from that in the visible
1.1 450 5650.00 range due to changes in glass dispersion and refractive index.
378-824-5 20X 0.40 20 10 0.7 0.65 1.2 0.24 x 0.32 450
0.56
378-825-5 50X 0.42 17 4 0.7 0.48 0.10 x 0.13
378-826-5 100X 0.50 12 2 0.6 0.24 0.05 x 0.06
378-863-5 50X 0.65 10 4 0.42 0.48 0.10 x 0.13
378-864-5 100X 0.70 10 2 0.39
0.24 0.05 x 0.06
*1 Field of view when using 24 mm eyepiece, *2 Field of view when using 1/2" CCD camera.
34 34 0.4 37.5 (W.D.) 0.6 20 (W.D.) 0.5 12 (W.D.) Unit: mm
24.6 24.4
25 24.8 24.6
32.2 32.2 25
32.2
34 34
57.5 75 83
5 95 378-822-5 5 95 378-824-5 5 95 378-826-5
(Parfocal distance) (Parfocal distance) (Parfocal distance)
1 30.5 (W.D.) 0.4 17 (W.D.)
24.6
25.2 24.4
32.2 25
32.2
34
64.5 78
5 95 378-823-5 5 95 378-825-5
(Parfocal distance) (Parfocal distance)
Near-Ultraviolet Corrected
M Plan Apo NUV for Bright Field Observation
Code No. Magnification Numerical Working Focal Resolving Focal View View field 2*2 Mass Price Note:
aperture distance distance power depth field 1*1 (mm) (g) These objectives are designed so that a workpiece's image can
(µm) be focussed within the focal depth even when the wavelength
(mm) (mm) (µm) (mm) used is changed anywhere from the visible range
(l = 620 nm) to the near-ultraviolet range (l = 355 nm).
378-809-5 10X 0.28 30.5 20 1.0 3.5 2.4 0.48 x 0.64 255 2730.00 Therefore The M Plan NUV Series are suitable for laser repair
using a high frequency laser beam.
J 378-817-4 20X 0.40 17 10 0.7 1.7 1.2 0.24 x 0.32 340 3950.00
0.42 15 4 0.7 1.6 0.48 0.10 x 0.13 350 3950.00
378-818-4 50X
378-819-4 100X 0.50 11 2 0.6 1.1 0.24 0.05 x 0.06 380 4390.00
378-888-4 50X 0.65 10 4 0.42 0.65 0.48 0.10 x 0.13 500 9690.00
*1 Field of view when using 24 mm eyepiece, *2 Field of view when using 1/2" CCD camera.
Unit: mm
34 34 0.5 30.5(W.D.) 34 34 2.6 15(W.D.)
25.2 24.4
32.2 25
32.2
64.5 80
5 95 378-809-5 5 95 378-818-4
(Parfocal distance) (Parfocal distance)
1.6 17(W.D.) 1.7 11(W.D.)
24 23.4
25 24.4
32.2 32.2
78 84
5 95 378-817-4 5 95 378-819-4
(Parfocal distance) (Parfocal distance)
J-25 Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.
Therefore the company reserves the right to change any or all aspects of any product specification without notice.
mitutoyo@mitutoyo-tools.ru www.mitutoyo-tools.ru