Ниже представлена эта же страница в формате, позволяющем производить копирование текста.
Mitutoyo - Полный каталог инструмента - 2014 Английский язык
для размещения заказа - mitutoyo@mitutoyo-tools.ru
Micrometers
SERIES 343 – Digimatic Caliper Anvil Micrometer
• Effective for measuring workpiece features where • Equipped with Ratchet Stop for constant Technical Data
access is difficult. measuring force. Flatness: 0.3 µm(.000012")
Parallelism*: (3+R/75) µm,
• Measuring faces: Carbide. [.00012+.00004(R/3)]"
Battery: SR44 (2 pcs) 938882
* R = max. range (mm/inch)
Note: Fractions rounded down
B Functions
343-350 Origin point setting (ABS measurement system):
Resets the ABS origin at the current spindle position to the
SPECIFICATIONS minimum value of the measuring range and switches to ABS
mode.
Inch/Metric
Zero setting (INC measurement system):
Code No. Range Resolution Accuracy* Price A brief press on the ZERO/ABS button sets display to zero at
343-350 0-25 mm (0-1") 0.001 mm (.00005") ±5 µm (±.00025") 428.00 the current spindle position and switches to the incremental
343-351 25-50 mm (1-2") ±6 µm (±.0003") 514.00 (INC) measuring mode. A longer press resets to the ABS
343-352 50-75 mm (2-3") ±7 µm (±.00035") 538.00 measuring mode.
343-353 75-100 mm (3-4") ±8 µm (±.0004") 570.00
Hold:
* Excluding quantizing error. Pressing the HOLD button freezes the current value in the
display. This function is useful for preserving a measurement
DIMENSIONS Unit: mm in situations of poor visibility where the instrument must be
11.5 17 moved away from the workpiece before the reading can be
c recorded.
Auto power ON/OFF:
The reading on the LCD disappears after this instrument is
idle for about 20 minutes, but the reading and measurement
mode are retained. Turning the spindle causes the reading to
reappear.
Data output:
Models equipped with this function have an output port for
transferring measurement data to a Statistical Process Control
(SPC) system.
Error alarm:
In the unlikely event of a display overflow or calculation
error, an error message is displayed and measurement stops.
Measurement cannot continue until the error is corrected.
Also, if the battery voltage drops below a certain point, the
battery indicator will turn on before measurement becomes
impossible, warning the user that the battery needs to be
replaced.
L b 11.3 47.2 2.3 3 41 Optioal Accessories
a
14 05CZA662: SPC data cable with pushbutton (1 m)
7.4 Thickness of jaw 3 58.50
3.4
05CZA663: SPC data cable with pushbutton (2 m)
25.7 5.9 70.40
12.5
06ADV380B: USB Input Tool Direct USB-ITN-B (2 m)
4 106.00
13
02AZD790B: SPC data cable for U-WAVE-T (160 mm)
6.35 52.20
18
02AZE140B: SPC data cable for U-WAVE-T and footswitch
(160/500 mm)
119.00
Range Labc
0-25 mm
25-50 mm 55.5
50-75 mm
75-100 mm 80.5 27.5 10.6 32.9
105.5
130.5
B-27 Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.
Therefore the company reserves the right to change any or all aspects of any product specification without notice.
mitutoyo@mitutoyo-tools.ru www.mitutoyo-tools.ru