Ниже представлена эта же страница в формате, позволяющем производить копирование текста.

Mitutoyo - Полный каталог инструмента - 2014 Английский язык

                                                                        для размещения заказа - mitutoyo@mitutoyo-tools.ru

 How to Read the Scale                                                                                                Measuring Force Limiting Device

Micrometer with standard scale (graduation: 0.01 mm)                                                                                               Audible in    One-
                                                                                                                                                   operation    handed Remarks
          (1)       45                   (1)	Sleeve scale reading	 7.	 mm                                                                                      operation
                                         (2)	Thimble scale reading	 + 0.37	mm
     05             40                                                                                                Ratchet stop
                    35                   	 Micrometer reading	 7.37	mm
                        (2)        Note) 0.37 mm (2) is read at the position where the sleeve                                                      Yes         Unsuitable  Audible clicking operation causes
                                                                                                                                                                           micro-shocks
                                         index line is aligned to the thimble graduations.
                    30

The thimble scale can be read directly to 0.01 mm, as shown above, but may                                            Friction thimble             No          Suitable    Smooth operation without shock or  B
also be estimated to 0.001 mm when the lines are nearly coincident because                                                          (F type)                               sound
the line thickness is 1/5 of the spacing between them.
                                                                                                                      Ratchet thimble
                             Approx. +1 µm                                    Approx. +2 µm                                         (T type)       Yes                    Audible operation provides
                                                                                                                                                               Suitable confirmation of constant measuring
                                                 (1)  30Index line
                                                      25                                                                                                                  force
     Index line     Thimble scale  0                  20 (2)                  Thimble scale                                                                               Audible operation provides
                                   8                                                                                                                           Suitable confirmation of constant measuring
                                                                                                                                                                          force
                                   6
                                   4
                                   2                                                                                  Ratchet thimble

Micrometer with vernier0 sc5ale (g1r5aduation: 0.001 mm)                                                                                           Yes

The vernier scale provided above the sleev1e0index line enables direct readings
to be made to within 0.001 mm.

     0                  30                       (1)	Sleeve scale reading	                   6.	 mm                    Measuring Face Detail
     8                  25
     6                                           (2)	Thimble scale reading	                          .21	 mm                                                          30’
(3)  4                  20 (2)
     2                                           (3)	Reading from the vernier scale marking
                        15
        05                                       	 and thimble graduation line	              + .003	mm                                                                      spindle
                        10                                                                                                                                                    6.35
                                                 	 Micrometer reading	                       6.213	mm                                  7.95 6.3

               (1)

     Note) 0.21 mm (2) is read at the position where the index line is between two                                                                      Carbide tip
        graduations (21 and 22 i0n this case). 03.0003 mm (3) is read at the position                                                                                  30’
        where one of         the(v3e) rnier8642  graduations  2a5ligns  with  one  of  the  thimble
        graduations.                                          20 (2)

Micrometer with mechanica0l-di5git dis1p5lay (digital step: 0.001 mm)                                                                                                       spindle
                                      Third d(e1c)imal p1la0ce on vernier scale ( 0.001 mm units)                                                                             8

                                                             5                                                                                           Carbide tip
                                                                                                                      These drawings above are for illustration only and are not to scale
                                                               6
                                                               4

                                               20

                             (1) 0 45

                    0 29 9

                             mm Vernier reading 0.004 mm (2)

                                                   Index line                   .004 mm      (2)
                                        Third decimal place                     .09 mm
                                        Second decimal place                    .9 mm        (1)
                                        First decimal place                    2. mm         *Indicates four digits.
                                        Millimetres                           00. mm
                                      + Tens of mm                             2.994 mm

                                       Counter reading

     Note) 0.004 mm (2) is read at the position where a vernier graduation aligns with
          one of the thimble graduation lines.

                                                                                                                                                   B-76

                                                                              mitutoyo@mitutoyo-tools.ru www.mitutoyo-tools.ru