Ниже представлена эта же страница в формате, позволяющем производить копирование текста.

Mitutoyo - Полный каталог инструмента - 2014 Английский язык

                                                          для размещения заказа - mitutoyo@mitutoyo-tools.ru

   Calipers

   SERIES 500 – ABSOLUTE Digimatic Coolant Proof Solar SuperCaliper

   •	Top-of-the-line digital caliper. Solar type caliper               •	Slider operation is smooth and comfortable.                                                                             Technical Data
   	 with no battery and IP67 protection assures                       •	The impact resistance of the display unit has
   	 waterproof reliability.                                           	 been increased for improved usability in                                                                                Repeatability: 		      0.01 mm
   •	With no annoying origin restoration necessary, a                  	 workshop conditions.
   	 measurement can be started any time and there                     •	Waterproof function makes this SuperCaliper                                                                             Quantizing error: 	 ±1 count
   	 is no restriction on operating speed.                             	 suitable for use in an environment containing
                                                                       	 large amounts of cutting fluid or coolant.                                                                              Dust/water protection
                                                                       •	Operability is equivalent to the mechanical type
                                                                       	 caliper.                                                                                                                level: 		              IP67*2
                                                                       •	This SuperCaliper uses components that do not
                                                                       	 contain harmful substances and is compatible                                                                            Power supply: 	        Solar cell*3
                                                                       	 with RoHS Directives.
                                                                                                                                                                                                 Scale type: 		         ABSOLUTE electromagnetic induction

                                                                                                                                                                                                 			                    linear encoder

                                                                                                                                                                                                 Max. response speed: 	Unlimited

            Insufficient               Sufficient    No need for                                                                                                                                 *2	Rustproofing treatment to be applied after use.
            illumination               illumination  origin set up                                                                                                                               *3	Can be used continuously above 60 lux ambient illumination.
                                   16.78 mm

   •	SPC data output models can be integrated                                                                                                                                                    Functions
   	 into statistical process control and measurement
   	 systems.                                                                                                                                                                                    ABSOLUTE system measurement:
                                                                                                                                                                                                 After power is turned ON, measurement can be started
D                                                                                                                                                                                                without zero-setting if origin-setting was previously
                                                                                                                                                                                                 performed. The ABS (absolute) origin position can be changed
                                                                                              201120740                                                                                          by the ORIGIN button.
             A
                 DB                                  500-784                                                                                                                                     Zero-setting (INC measurement mode):
                                                                                                                                                                                                 Displayed value can be set to zero at any arbitrary position of
                                                                                                                                                                           0                     the slider for comparative measurements.

                                                                                                                                     E                                                           Data output:
                                                                                                                                                                                                 Models equipped with this function have an output port for
                                                                                                                                                                                                 transferring measurement data to a Statistical Process Control
                                                                                                                                                                                                 (SPC) system.

                                                                                                                                                                                                 Inch/mm selection:
                                                                                                                                                                                                 Switches the units of measurement (at any time).

                                                                                                                                                                                                 Alerts:
                                                                                                                                                                                                 If the ambient illumination and the stored charge voltage are
                                                                                                                                                                                                 insufficient an error message is displayed and measurement
                                                                                                                                                                                                 stops. If contamination on the surface of the scale causes
                                                                                                                                                                                                 a calculation error, an error message is displayed and
                                                                                                                                                                                                 measurement stops.

   SPECIFICATIONS

    Inch/Metric

   Code No.                        Range                 Resolution           Accuracy*1                                                                                    Mass          Price
                                                     0.01 mm (.0005")         ±0.02 mm
   With SPC data output                              0.01 mm (.0005")         ±0.02 mm                                                                                      180 g      210.00
                                                                                                                                                                            210 g      239.00
   500-786                0-150 mm (0-6")
                                                                                                                                                                            180 g      156.00
   500-787                0-200 mm (0-8")                                                                                                                               210 g      204.00

   Without SPC data output

   500-784                0-150 mm (0-6")

   500-785                0-200 mm (0-8")

   *1 Excluding quantizing error.

   DIMENSIONS

                                                                                                                                                                                       Unit: mm  Smooth slider movement makes for
                                                                                                                                                                                                 comfortable operation.
                                                                    C
                                                                                                                                                                                                 High quality guide surface finish for smooth slider movement.

                                                                                                                                                                                                 Conventional                           SuperCaliper

                                                                                                                                                                                                 Ra: 0.126 m                           Ra: 0.07 m

                                                                       Range                  ABC                                                                                  D   E
                                                                                                                                                                                   40  16
                                                                       0-150 mm             21 16.5 233                                                                          50

                                                                       0-200 mm             24.5 20 290

                                                                       Jaw thickness: 3.5 mm

                                                     D-3                                          Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.
                                                                                                                                Therefore the company reserves the right to change any or all aspects of any product specification without notice.