Mitutoyo - Полный каталог инструмента - 2014 Английский язык

                                                        для размещения заказа - mitutoyo@mitutoyo-tools.ru

Optional Accessories                                    About the charge function                                                              Illumination (lx)  Site (possible operations)
                                                                                                                                                         1500
(Only for models with data output function)             The minimum illumination required in the
                                                        uncharged state is 60 lux.                                                                  1000          Design room, drafting room
05CZA624:	 SPC data cable with pushbutton (1 m)                                                                                                                        (Fine visual work)
		 58.50                                               As shown in the table at right, this SuperCaliper
                                                        can be used with confidence in a normal work                                                750 Conference room, control room
05CZA625:	 SPC data cable with pushbutton (2 m)         environment.
		 70.40                                                                                                                                           500 (Usual manufacturing environment)
                                                        The charge function allows the operator to use
06ADV380A:	 USB Input Tool Direct USB-ITN-A (2 m)       the SuperCaliper without interrupting work                                                  300           (Normal visual work)
		 106.00                                              even if the ambient illumination is temporarily
                                                        insufficient.                                                                               200           Machine room, electric room, lecture hall
02AZD790A:	 SPC data cable for U-WAVE-T (160 mm)                                                                                                                          (Rough visual work)
		 52.20                                               In the fully charged state this SuperCaliper                                                150
                                                        can operate for approximately one hour in an                                                              Corridor, passage, stairs
02AZE140A:	 SPC data cable for U-WAVE-T and footswitch  environment of 50 lux illumination (less than the                                           100           (Very rough visual work)
		 (160/500 mm)                                         minimum necessary illumination intensity).
		 114.00                                                                                                                                          75
                                                        The time necessary for full charge varies according
                                                        to the charging conditions. If the SuperCaliper                                             50 Emergency staircase, warehouse
                                                        is left unused in an illumination of 500 lux                                                30 (Loading, unloading work)
                                                        (usual for manufacturing environments), it takes
                                                        approximately one hour to reach full charge.                                                       20                                                       D
                                                                                                                                               Excerpts from JIS Z 9110 Artificial Illumination Intensity Standard

                                                        Air leak test equipment for water resistance inspection

                                                        Generally, an air leak test is used for evaluating water resistance.

                                                        Procedure: Place the measuring tool inside the capsule and seal it. Then fill the capsule and the test
                                                        chamber with air at the required pressure and close the isolating valves. If there is no leak in the
                                                        measuring tool, the differential pressure sensor will read zero, because the amount of air inside the test
                                                        chamber is unchanging. However, if there is a leak in the measuring tool, the differential pressure sensor
                                                        will show a non-zero reading due to a decrease in pressure inside the test chamber as air leaks into the
                                                        tool. By detecting this differential pressure, GO/NG judgement for the severity of the leak is performed.
                                                        This air leak test is performed for all coolant proof calipers and coolant proof micrometers.

                                                                 Air supply

                                                                 Isolating  Isolating
                                                                 valves     valves

                                                        Capsule                         Test chamber

                                                                 Differential                            Air leak test equipment for coolant proof caliper
                                                                 pressure sensor
                                                                                         Master
                                                                           Valve Valve

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.  D-4
Therefore the company reserves the right to change any or all aspects of any product specification without notice.

                                                                                mitutoyo@mitutoyo-tools.ru www.mitutoyo-tools.ru