   Calipers

   SERIES 500 – ABSOLUTE Digimatic Coolant Proof Caliper

   •	Can be used in workshop conditions exposed to                                                            •	Can measure outside and inside dimensions,                           Technical Data
   	 coolant, water, dust or oil. Other specifications                                                        	 depth, and steps.
   	 and price are the same as the conventional                                                               •	The automatic power-on/off function shuts down                       Resolution: 		         0.01 mm (.0005")
   	 products. 100% inspection by air leak test is                                                            	 the LCD display after 20 minutes inactivity, but
   	 performed to ensure quality and reliability.                                                             	 the ABS scale unit origin is stored. Power is                        Repeatability: 		      0.01 mm
   •	Large LCD characters make the display easy to                                                            	 restored when the slider is moved.
   	 read.                                                                                                    •	A convenient interface input tool is available                       Quantizing error: 	 Not including ±1 count
   •	Easy to use – advanced design styling with only 1                                                        	 so that measurement data can be converted to
   	 button.                                                                                                  	 keyboard signals and input directly to commercial                    Dust/water protection
   •	Incorporates Mitutoyo's ABSOLUTE measurement                                                             	 spreadsheet software.
   	 system. No need to reset the origin.                                                                     •	An inspection certificate is supplied as standard.                   level: 		              IP67*1
   •	SPC data output models can be integrated                                                                 	 (However, this cannot be used as a calibration
   	 into statistical process control and measurement                                                         	 certificate as it is undated.)                                       Scale type: 		         ABSOLUTE electromagnetic induction
   	 systems.
                                                                                                                                                                                     			                    linear encoder

                                                                                                                                                                                     Max. response speed:	 Unlimited

                                                                                                                                                                                     Battery: 		            SR44 (1 pc.), 938882

                                                                                                                                                                                     Battery life: 		       Approx. 3 years under normal use (1 	

                                                                                                                                                                                     			                    year: over 300 mm models)

                                                                                                                                                                                     *1	Rustproofing treatment to be applied after use.

D                                                                                                                                                                                    Functions

                                                                                                                                                                                     ABSOLUTE system measurement:
                                                                                                                                                                                     After power is turned ON, measurement can be started
                                                                                                                                                                                     without zero-setting if origin-setting was previously
                                                                                                                                                                                     performed. The ABS (absolute) origin position can be changed
                                                                                                                                                                                     by the ORIGIN button.

                                                                                                                                                                                     Zero-setting (INC measurement mode):
                                                                                                                                                                                     Displayed value can be set to zero at any arbitrary position of
                                                                                                                                                                                     the slider for comparative measurements.

               A                                                                                                                                                201120740            Auto ON/OFF:
                      DB                                                                                                                                                             The reading on the LCD disappears after this instrument is idle
                                                                                                              500-753-10                                                             for a short time, but the origin point is retained. Moving the
                                                                                                            E0                                                                       slider causes the reading on the LCD to reappear.
                                                                                                              500-737-10
                                                                                                                                                                                     Data output:
                                                                                                                                                                                     Models equipped with this function have an output port for
                                                                                                                                                                                     transferring measurement data to a Statistical Process Control
                                                                                                                                                                                     (SPC) system.

                                                                                                                                                                                     Inch/mm selection:
                                                                                                                                                                                     Switches the units of measurement (at any time).

                                                                                                                                                                                     Alerts:
                                                                                                                                                                                     In the unlikely event of a display overflow or calculation
                                                                                                                                                                                     error, an error message is displayed and measurement stops.
                                                                                                                                                                                     Measurement cannot continue until the error is corrected.
                                                                                                                                                                                     If the battery voltage drops below a certain point, the
                                                                                                                                                                                     battery indicator will turn on before measurement becomes
                                                                                                                                                                                     impossible, warning the user that the battery needs to
                                                                                                                                                                                     be replaced. If contamination on the surface of the scale
                                                                                                                                                                                     causes a calculation error, an error message is displayed and
                                                                                                                                                                                     measurement stops.

                                                                                                                                                                                     Optional Accessories

   DIMENSIONS                                                                                                                                                                        05CZA624:	 SPC data cable with pushbutton (1 m)
                                                                                                                                                                                     		 58.50
                                                                                                                                                                           Unit: mm
                                                                                                                                                                                     05CZA625:	 SPC data cable with pushbutton (2 m)
               C                                                                                                                                                                     		 70.40

                                                                                                                                                                                     06ADV380A:	 USB Input Tool Direct USB-ITN-A (2 m)
                                                                                                                                                                                     		 106.00

                                                                                                                                                                                     02AZD790A:	 SPC data cable for U-WAVE-T (160 mm)
                                                                                                                                                                                     		 52.20

                                                                                                                                                                                     02AZE140A:	 SPC data cable for U-WAVE-T and footswitch
                                                                                                                                                                                     		 (160/500 mm)
                                                                                                                                                                                     		 114.00

                                                                                                              Range       ABCD                                             E
                                                                                                                                                                           16
                                                                                                              0-150 mm  21 16.5 233 40                                   20

                                                                                                              0-200 mm  24.5 20 290 50

                                                                                                              0-300 mm  27.5 21.8 404 64

                                                                                                              Outside jaw thickness: 3.5 mm (500-714-10: 3.8 mm)

                  D-5                                                                                                                    Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.
                                                                                                                                                                       Therefore the company reserves the right to change any or all aspects of any product specification without notice.

                                                                                                              mitutoyo@mitutoyo-tools.ru www.mitutoyo-tools.ru