   Calipers                                                                                                                                                          Technical Data

   SERIES 552 – ABSOLUTE Digimatic Long Jaw Carbon Fibre Caliper                                                                                                     Scale type: 		    ABSOLUTE electromagnetic induction

   •	A lightweight Digimatic caliper that uses CFRP (Carbon Fibre Reinforced Plastics) in the beam and jaws.
   •	Data output function allows integration into statistical process control and measurement systems.

                                                                                                                                                                     				              linear encoder

                                                                                                                                                                     Max. response speed:	 Unlimited

                                                                                                                                                                     Battery: 		       SR44 (1 pc.), 938882

                                                                                                                                                                     Battery life: 		  Approx. 5,000 hours in continuous use

                                                                                                                                                                     Dust/water

                                                                                                                                                                     protection level: 	 IP66*3

                                                                                                                                                                     Standard accessory: 	 Jaw clamps (2 pcs.), 05GZA033

                                                                                                                                                                     *3	Rustproofing treatment to be applied after use.

                                                                                      • Dust-tight and water                                                         Functions
                                                                                        protected IP66
                                                                                                                                                                     ABSOLUTE system measurement:
                                                                                    FE                                               000000716                       After power is turned ON, measurement can be started
                                                                                                   HG                                                                without zero-setting if origin-setting was previously
                                                 552-160-10                                                                                                          performed. The ABS (absolute) origin position can be changed
                                                                                                                                    1                                by the ORIGIN button.
D
                                                                                                                                                                     Zero-setting (INC measurement mode):
   SPECIFICATIONS                                                                                                                                                    Displayed value can be set to zero at any arbitrary position of
                                                                                                                                                                     the slider for comparative measurements.
   Inch/Metric
                                                                                                                                                                     Auto ON/OFF:
   Code No.                                Range*1                     Resolution                                                        Accuracy*2           Price  The reading on the LCD disappears after this instrument is idle
                                                                    0.01 mm/.0005"                                                                      930.00    for a short time, but the origin point is retained. Moving the
   552-160-10   0 (20)-450 mm/0 (.5")-18"                                                                                      ±0.06 mm/±.0025"  1070.00    slider causes the reading on the LCD to reappear.
                                                                                                                                                         1530.00
   552-161-10   0 (20)-600 mm/0 (.5")-24"                                                                                      ±0.07 mm/±.003"   1750.00    Data output:
                                                                                                                                     ±0.11 mm/±.0045"  2230.00    Models equipped with this function have an output port for
   552-162-10   0 (20)-1000 mm/0 (1")-40"                                                                                      ±0.14 mm/±.0055"              transferring measurement data to a Statistical Process Control
                                                                                                                                                          Unit: mm   (SPC) system.
   552-163-10   0 (20)-1500 mm/0 (1")-60"
                                                                                                                                                          H          Data hold:
   552-164-10   0 (20)-2000 mm/0 (1")-80"                                                                                                           8          By using the data hold unit (option), the displayed value can
                                                                                                                                                                     be held. This cannot be used with the data output function.
   *1 ( ): Minimum dimension in inside measurement.
   *2 Excluding quantizing error.                                                                                                                                    Presetting (ABS INC measurement mode):
                                                                                                                                                                     Displayed value can be set to any arbitrary value.
   DIMENSIONS                                                    A
                                                               D                                                                                                     Offsetting:
                                        C                                                                                                                            Automatically adds the thickness of the inside jaws to the
                                                                                                                                                                     measured value so that the result can be read directly, without
                                                 100                                                                                                                calculation.
                                                    200
                                                                                                                                                                     Inch/mm selection:
                   24                                                                                                                                                Switches the units of measurement (at any time).

                                   B                                                                                                            8                    Alerts:
                       R10                                                                                                                                           In the unlikely event of a display overflow or calculation
                                                 8                                                                                                                   error, an error message is displayed and measurement stops.
                                                                                                                                                                     Measurement cannot continue until the error is corrected.
   Range                                   AB                   CDE F                                                                              G                 If the battery voltage drops below a certain point, the
   0-450 mm                                                  89 91.8 65.5 173                                                                    25                battery indicator will turn on before measurement becomes
   0-600 mm                              680                                                                                                                       impossible, warning the user that the battery needs to
   0-1000 mm                             830                 110 113.8 73 170.5                                                                  32                be replaced. If contamination on the surface of the scale
   0-1500 mm                                                                                                                                                       causes a calculation error, an error message is displayed and
   0-2000 mm                                                                                                                                                       measurement stops.

                                                                                                                                                                     Optional Accessories

                                                                                                                                                                     05CZA624:	 SPC data cable with pushbutton (1 m)
                                                                                                                                                                     		 58.50

                                                                                                                                                                     05CZA625:	 SPC data cable with pushbutton (2 m)
                                                                                                                                                                     		 70.40

                                                                                                                                                                     06ADV380A:	 USB Input Tool Direct USB-ITN-A (2 m)
                                                                                                                                                                     		 106.00

                                                                                                                                                                     02AZD790A:	 SPC data cable for U-WAVE-T (160 mm)
                                                                                                                                                                     		 52.20

                                                                                                                                                                     02AZE140A:	 SPC data cable for U-WAVE-T and footswitch
                                                                                                                                                                     		 (160/500 mm)
                                                                                                                                                                     		 114.00

                                                         6.35

                                           1280

                                           1790 12.7                                                                                                     12

                                           2300

                                                               D-21                             Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.
                                                                                                                              Therefore the company reserves the right to change any or all aspects of any product specification without notice.

                                                                     mitutoyo@mitutoyo-tools.ru www.mitutoyo-tools.ru
Заявка