Calipers Technical Data
SERIES 552 – ABSOLUTE Digimatic Long Jaw Carbon Fibre Caliper Scale type: ABSOLUTE electromagnetic induction
• A lightweight Digimatic caliper that uses CFRP (Carbon Fibre Reinforced Plastics) in the beam and jaws.
• Data output function allows integration into statistical process control and measurement systems.
linear encoder
Max. response speed: Unlimited
Battery: SR44 (1 pc.), 938882
Battery life: Approx. 5,000 hours in continuous use
Dust/water
protection level: IP66*3
Standard accessory: Jaw clamps (2 pcs.), 05GZA033
*3 Rustproofing treatment to be applied after use.
• Dust-tight and water Functions
protected IP66
ABSOLUTE system measurement:
FE 000000716 After power is turned ON, measurement can be started
HG without zero-setting if origin-setting was previously
552-160-10 performed. The ABS (absolute) origin position can be changed
1 by the ORIGIN button.
D
Zero-setting (INC measurement mode):
SPECIFICATIONS Displayed value can be set to zero at any arbitrary position of
the slider for comparative measurements.
Inch/Metric
Auto ON/OFF:
Code No. Range*1 Resolution Accuracy*2 Price The reading on the LCD disappears after this instrument is idle
0.01 mm/.0005" 930.00 for a short time, but the origin point is retained. Moving the
552-160-10 0 (20)-450 mm/0 (.5")-18" ±0.06 mm/±.0025" 1070.00 slider causes the reading on the LCD to reappear.
1530.00
552-161-10 0 (20)-600 mm/0 (.5")-24" ±0.07 mm/±.003" 1750.00 Data output:
±0.11 mm/±.0045" 2230.00 Models equipped with this function have an output port for
552-162-10 0 (20)-1000 mm/0 (1")-40" ±0.14 mm/±.0055" transferring measurement data to a Statistical Process Control
Unit: mm (SPC) system.
552-163-10 0 (20)-1500 mm/0 (1")-60"
H Data hold:
552-164-10 0 (20)-2000 mm/0 (1")-80" 8 By using the data hold unit (option), the displayed value can
be held. This cannot be used with the data output function.
*1 ( ): Minimum dimension in inside measurement.
*2 Excluding quantizing error. Presetting (ABS INC measurement mode):
Displayed value can be set to any arbitrary value.
DIMENSIONS A
D Offsetting:
C Automatically adds the thickness of the inside jaws to the
measured value so that the result can be read directly, without
100 calculation.
200
Inch/mm selection:
24 Switches the units of measurement (at any time).
B 8 Alerts:
R10 In the unlikely event of a display overflow or calculation
8 error, an error message is displayed and measurement stops.
Measurement cannot continue until the error is corrected.
Range AB CDE F G If the battery voltage drops below a certain point, the
0-450 mm 89 91.8 65.5 173 25 battery indicator will turn on before measurement becomes
0-600 mm 680 impossible, warning the user that the battery needs to
0-1000 mm 830 110 113.8 73 170.5 32 be replaced. If contamination on the surface of the scale
0-1500 mm causes a calculation error, an error message is displayed and
0-2000 mm measurement stops.
Optional Accessories
05CZA624: SPC data cable with pushbutton (1 m)
58.50
05CZA625: SPC data cable with pushbutton (2 m)
70.40
06ADV380A: USB Input Tool Direct USB-ITN-A (2 m)
106.00
02AZD790A: SPC data cable for U-WAVE-T (160 mm)
52.20
02AZE140A: SPC data cable for U-WAVE-T and footswitch
(160/500 mm)
114.00
6.35
1280
1790 12.7 12
2300
D-21 Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances.